MV-MQ

MVP/A0-0A

Photo.M18,AC-NO,Cable,Reflex
Photoelectric sensor M18 Polarized 3,5 m 20..253Vac NO plast. cable 2m axial

M18 AC multivoltage output photoelectric sensors

Overview

  • Wide range of models: diffuse, retro-reflective, polarized, through-beam
  • Through-beam models with high sensing range
  • Retro-reflective models with polarized light (with visible beam)
  • M12 plug cable exit in axial or right angle shape
  • Low leakage current and high output current
  • IP67 protection degree
  • Complete protection against electrical damage

Technical Features

Detection properties
Nominal sensing distance 3,5m
Thermal drift of Sr ≤10%Sr
Repeat Accuracy 5%
Sensitivity adjustment No
Application
Function Principle Polarized
Notes On RL110 reflector
Optic position Axial
Outputs
Output type TRIAC NO
Output Function NO
Switching frequency 25Hz
Response time 20ms
Electrical data
Operating Voltage 20...253VAC/50-60Hz
No-Load supply current ≤ 30mARMS
Load current 5…300mARMS
Leakage current 6A
Output voltage drop ≤3V@Iload=300mARMS
Max ripple content ≤10%
LED indicators Red (status output)
Time delay before availability ≤200ms
Emission LED Red (660nm)
Interference to external light 3.000lux (incandescent lamp), 10.000lux (sunlight)
Mechanical data
Dimensions M18x1/L=78,9mm
Housing material PBT / PC cable exit
Weight 100g
Connections 2m PVC cable
Active Head Material PMMA
Tightening torque 1Nm
Operating temperature - 25°C…+ 60° C (without freeze)
Diameter/Dimension M18
Test/Approvals
Approvals CE cURus
EMC compatibility EN 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27
Degree of protection IP67
Accessories
Supplied Accessories Nuts M18 x 1
Generical Data
Dimensions M18x1/L=78,9mm
Operating Temperature - 25°C…+ 70°C (Without freeze)
Mechanical Protection IP67

Connections

Eletrical diagram

Others

Dimensions
Response curves

Downloads for MVP/A0-0A