Inductive sensor M5 Sn 1,5 mm NO/PNP cable 2m axial

M5 cylindrical miniaturized inductive sensors

Overview

  • Extremely reduced models: M5 x 30 mm (cable) / 38 mm (plug) lenght
  • Operating voltage: 10...30 Vcc
  • Output current: 100 mA
  • LED output indicator
  • Totally protected against electrical damages
  • Cable and M8 plug output
  • Stainless steel housing

Technical Features

Detection properties
Nominal sensing distance 1,5mm
Operanting distance 0…1,21mm
Standard target 5x5mm FE360
Correction Factor copper: 0,33 ± 10% / aluminium: 0,27 ± 10% / brass: 0,34 ± 10% / stainless steel: 0,66 ± 10%
Thermal drift of Sr < 10%
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis 1 … 20%
Application
Description M5 standard flush mount
Functions Proximity
Outputs
Output type PNP
Output Function NO
Switching frequency 5kHz
Electrical data
Operating Voltage 10...30Vdc
No-Load supply current ≤ 10mA
Load current ≤ 100mA
Leakage current ≤ 10μA
Output voltage drop ≤ 1,5V @100mA
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 50ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Impulsive Overvoltage Protection Yes
Protection against inductive loads Yes
Mechanical data
Mounting Shielded
Dimensions M5 x 0,5 / L = 30,2mm
Weight 30g
Housing Material AISI303 Stainless Steel
Connections 2m PVC Cable
Active Head Material PBT
Tightening torque 2Nm
Operating temperature -25°C…+70°C
Material AISI303 Stainless Steel
Diameter/Dimension M5
Test/Approvals
Approvals CE cULus
EMC compatibility IEC 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27
Degree of protection IP67
Accessories
Supplied Accessories 2 nuts M5x0.5
Generical Data
Dimensions M5 x 0,5 / L = 30,2mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67

Connections

Eletrical diagram

Others

Dimensions
Response curves
Installation