| Nominal sensing distance | 5m (ExG=2) |
| Thermal drift of Sr | ≤ 10% |
| Resolution | Single-beam |
| controlled height | Single-beam |
| Effective Aperture Angle | Typical ±1,8° |
| Function Principle | Receiver |
| Notes | not working with SBCR03 control unit. To be used with external safety control unit with automatic optics test function |
| Description | M18 Type 4 Safety Photocell Receiver |
| Type | Type 4 safety photocell |
| SIL | 3 |
| SILCL | 3 |
| PL | e |
| MTTFd | 20 years |
| Output type | Totem-pole |
| Resposnse time for light/dark transition | 200µs |
| Resposnse time for dark/light transition | 400µs |
| Operating Voltage | 10 … 30 Vdc |
| No-Load supply current | ≤ 25mA |
| Load current | ≤ 70mA |
| Output voltage drop | 2,5V @ 50mA |
| Max ripple content | ≤ 5 Vpp |
| LED indicators | Yellow (alignement) |
| Dimensions | M18 |
| Housing material | PBT |
| Connections | M12 plug |
| Active Head Material | Glass |
| Operating temperature | -20°C … +55°C |
| Storage temperature | -40°C … +75°C |
| Humidity | 15% … 95% |
| Approvals | CE, TÜV |
| Shocks and vibrations | 10g - 16ms (according to IEC600068-2-29) 10Hz…55Hz - 1 oct/min - 0,35mm (according to 60068-2-6) |
| Degree of protection | IP67 |
| Supplied Accessories | 2 x nuts |
| Dimensions | M18 |
| Operating Temperature | -20…+55°C (Without freeze) |
| Humidity | 15% … 95% |
| Mechanical Protection | IP67 |
| Disegno 2D PDF | 8,10E-10 |