Nominal sensing distance | 5m (ExG=2) |
Thermal drift of Sr | ≤ 10% |
Resolution | Single-beam |
controlled height | Single-beam |
Effective Aperture Angle | ≤ ±5° |
Effective Aperture Angle | Typical ±1,8° |
Function Principle | Receiver |
Notes | not working with SBCR03 control unit. To be used with external safety control unit with automatic optics test function |
Description | M18 Type 2 Safety Photocell Receiver |
Type | Type 2 safety photocell |
SIL | 1 |
SILCL | 1 |
PL | c |
PFHd | 1,00E-06 |
MTTFd | 20 years |
Output type | Totem-pole |
Resposnse time for light/dark transition | 200µs |
Resposnse time for dark/light transition | 400µs |
Operating Voltage | 10 … 30 Vdc |
No-Load supply current | ≤ 25mA |
Load current | ≤ 70mA |
Output voltage drop | 2,5V @ 50mA |
Max ripple content | ≤ 5 Vpp |
LED indicators | Yellow (alignement) |
Dimensions | M18 |
Housing Material | PBT |
Connections | M12 plug |
Active Head Material | Glass |
Operating temperature | -20°C … +55°C |
Storage temperature | -40°C … +75°C |
humidity | 15% … 95% |
Approvals | CE, TÜV |
Shocks and vibrations | 10g - 16ms (according to IEC600068-2-29) 10Hz…55Hz - 1 oct/min - 0,35mm (according to 60068-2-6) |
Degree of protection | IP67 |
Supplied Accessories | 2 x nuts |
Dimensions | M18 |
Operating Temperature | -20…+55°C (Without freeze) |
Humidity | 15% … 95% |
Mechanical Protection | IP67 |