| Nominal sensing distance | According to the sensors used: SH4/*-**IA up to 10m TH6/*-*IA up to 60m |
| Effective Aperture Angle | n/a |
| Function Principle | Control unit |
| Available functions | Manual/Automatic Restart, EDM |
| Description | Compact standard |
| Max. number of sensors connected | 6 x SH4_IA/TH6_IA pairs |
| State lamp output | 1 x incandescent lamp (1 … 10W, 24Vdc) |
| Functions | Safety Control Unit + muting |
| Type | Type 2 safety control unit (A/M) |
| SIL | 1 |
| SILCL | 1 |
| PL | c |
| PFHd | 1,00E-06 |
| MTTFd | 20 years |
| Output type | 2 x PNP-NO (OSSD safety output) with EDM |
| Response time | ≤ 12 ms |
| Response Time (Test imput) | ≤ 30ms |
| Tempo di Risposta (Muting function) | ≤ 270ms |
| Recovery time | ≤ 50ms |
| Operating Voltage | 24 Vdc ± 20% |
| No-Load supply current | 100mA |
| Load current | ≤ 500mA each output |
| Output voltage drop | 2,5V @ 500mA |
| Cabel Length (Power Supply/Output) | ≤ 30m (cable section 0,5mm2) ≤ 60m (cable section 2,5mm2) |
| Cable Length (sensors) | ≤ 100m (cable section 2mm2) |
| Ripple | ≤ 5% |
| Power Consumption | 4W (without lamps/loads) |
| Dimensions | 99 x 105 x 100mm |
| Housing Material | ABS UL VO |
| Connections | 1 x terminals bar |
| Operating temperature | 20°C … +60°C (without freeze) |
| Storage temperature | -25…+ 70°C |
| humidity | 15% … 95% (no condensation) |
| Approvals | CE, TÜV |
| Degree of protection | IP20 |
| Dimensions | 99 x 105 x 100mm |
| Operating Temperature | 20…+60°C (without freeze) |
| Humidity | 15% … 95% (no condensation) |
| Mechanical Protection | IP20 |