Nominal sensing distance | 4mm | |
Operanting distance | 0…3,24mm | |
Standard target | 12x12mm FE360 | |
Correction Factor | copper: 0,30 / aluminium: 0,35 / brass: 0,40 / stainless steel: 0,75 | |
Thermal drift of Sr | < 10% | |
Repeat Accuracy | < 5% (UB 24V Ta=23°C ±5°C) | |
Hysteresis | 1 … 20% |
Description | M12 standard flush mount | |
Functions | Proximity |
Output type | PNP | |
Output Function | NO + NC | |
Switching frequency | 2kHz |
Operating Voltage | 10...30Vdc | |
No-Load supply current | ≤ 15mA | |
Load current | ≤ 200mA | |
Leakage current | ≤ 15μA | |
Output voltage drop | ≤ 2V @200mA | |
Max ripple content | ≤ 10% | |
LED indicators | Yellow LED output state | |
Time delay before availability | ≤ 50ms | |
Short-circuit protection | Yes | |
Reverse Polarity Protection | Yes | |
Impulsive Overvoltage Protection | Yes | |
Protection against inductive loads | Yes |
Mounting | Shielded | |
Weight | 30g | |
Housing Material | AISI316L Stainless Steel | |
Connections | M12 Plug | |
Active Head Material | PPS | |
Tightening torque | 25Nm | |
Material | AISI316L Stainless Steel | |
Diameter/Dimension | M12 |
Approvals | CE cULus ECOLAB DIVERSEY II 3G Ex nA IIC T5 Gc II 3D Ex tc IIIB T85°C Dc | |
EMC compatibility | IEC 60947-5-2 | |
Shocks and vibrations | Vibration IEC 60068-2-6 / Shock IEC 60068-2-27 |
Supplied Accessories | 2 nuts M12x1 |
Dimensions | M12 x 1 / L = 64,6mm | |
Operating Temperature | -40°C…+80°C (up to 100°C for short exposure during cleaning process) | |
Mechanical Protection | IP67 |