Stainless steel

95B066490

IS-08-N1-03

Non-contact detection Cost effective and reliable detection of any metal part

  • Standard proximity M4, M5, M8, M12, M18, M30
  • Double range (i.e. M12 4mm, M18 14mm, M30
  • 20mm)
  • Unshielded or shielded models for flush mounting
  • Nickel brass or stainless steel short and long
  • housing
  • Ecolab and Diversey certifications for industrial
  • detergents
  • Multi-voltage, Metal face, Weld field immune models
  • NO/NC, NPN or PNP output and programmable
  • versions.



Technical features

Detection properties

Nominal sensing distance 2mm
Operanting distance 0…1,62mm
Standard target 8x8mm FE360
Correction Factor copper: 0,4…0,5 / aluminium: 0,4…0,6 / brass: 0,5…0,7 / stainelss steel: 0,7…1,05
Repeat Accuracy < 3% (UB 24V Ta=23°C ±5°C)
Hysteresis < 10%

Application

Description M8 short case no-flush mount
Functions Proximity

Outputs

Output type PNP
Output Function NO
Switching frequency 1kHz
Response time 0,5

Electrical data

Operating Voltage 10...30Vdc
No-Load supply current ≤ 10mA
Load current 100mA
Output voltage drop ≤ 1,2V @100mA
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 50ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Emission ≥100kHz
Protection against inductive loads Yes

Mechanical data

Mounting Unshielded
Dimensions Ø8X44
Housing Material Stainless steel
Connections 2m PVC Cable
Active Head Material LCP
Tightening torque 2Nm
Material Stainless steel
Diameter/Dimension M8

Test/Approvals

Approvals CE cULus

Accessories

Supplied Accessories 2 nuts M8x1

Generical Data

Dimensions Ø8 / L = 44mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP69K