Beam angle | ± 15° | |
Sensibility | 1 sheet of 80g/m2 white paper | |
Tilting hysteresis | 7mm | |
Optics diameter | 3mm |
Output type | 2 x complementary PNP | |
Switching frequency | 100 hz with 1/1 dark-light | |
Sampling period | 4ms | |
4 optical scan period | 600µs | |
Response time outputs ONO and ONC | 4,7ms | |
Response time contact output A | 8ms (open); 500ms (close) |
Operating Voltage | 10...30Vdc | |
No-Load supply current | ≤ 70mA | |
Load current | ≤ 300mA | |
Leakage current | ≤ 10µA | |
Output voltage drop | ≤ 2,5V @ Iload = 100mA | |
Max ripple content | < 5Vpp | |
Emission | infrared | |
Interference to external light | 10000 lux (artificial light) | |
Optical power class | 1 (no danger) | |
Maximum capacitance load | 300mA | |
Test input levels (expected, but not connected) | LO ≤ 5V (or open), HI * 15V according to IEC61131-2 (2007) | |
VDE protection class | III (max. voltage 50VAC), 500V (insulation) | |
Output A (alarm) | Electromechanical contact, 1A, 30Vdc, no short circuit protection |
Dimensions | 26,4 x 83 x 162mm | |
Weight | 200g | |
Housing Material | PC | |
Connections | 2 x cable | |
Operating temperature | -20°C … + 55°C | |
Storage temperature | -40°C … +75°C | |
humidity | 15% … 95% |
Approvals | CE | |
EMC compatibility | Conforming with EMC directive according with EN60947-5-2 | |
Shocks and vibrations | shock resistance according to IEC60068-2-27: 3 axes x 6, half sine, Acc: 30g; Dur: 11s vibration resistance according IEC60068-2-6: freq:10…55hz; Ampl:0,5mm; Sweep:5min; Fr: 3x30min | |
Degree of protection | IP67 |
Dimensions | 26,4 x 83 x 162mm | |
Operating Temperature | -20°C … + 55°C | |
Humidity | 15% … 95% | |
Mechanical Protection | IP67 |