SG BODY REFLECTOR BASE / MUTING

957951050

SG4-RB4-120-OO-W

Retroreflective type 4 safety light grid for body detection

  • One active and one passive unit to reduce wiring and installation costs
  • Robust housing for harsh environments
  • Easy installation and alignment
  • Reflective muting arms included in L and T muting version
  • All advanced features associated to muting function
  • 2, 3, 4 beams for body protection
  • Controlled heights 500, 800, 900 and 1200 mm
  • Up to 8 m operating distance
  • Simple configuration through DIP switches
  • Integrated muting lamp (muting models)
  • Anti-interference coding
  • External muting enable signal
  • Edged or triggered muting dependent override



Technical features

Detection properties

Nominal sensing distance 0,5 … 8 m
Resolution 400mm
controlled height 1200 mm
number of rays 4
Sensitivity adjustment Dip-switch
Effective Aperture Angle ≤ ±2,5°

Application

Function Principle Transceiver (Active side)
Available functions Manual/Automatic Restart, EDM, L/T Muting, Override, Muting Enable, Muting Filter
Description Big RRX active unit
Functions Body protection 4 beams muting

Safety parameters

Type Type 4 safety light curtain (A/M)
SIL 3
SILCL 3
PL e
PFHd 8,57E-09
MTTFd 439 years
SFF 97,50%

Outputs

Output type 2 x PNP-NO (OSSD safety output) with EDM
Response time 12 ms

Electrical data

Operating Voltage 24 Vdc ± 20%
Load current ≤ 500mA each output
Emission Infrared LED (950 nm wavelength)
Interference to external light According to IEC 61496-2
Power Consumption - Receiver ≤ 6,5W (no load)
Power Consumption - Emitter n/a
Cabel Length (Power Supply/Output) ≤ 70m

Mechanical data

Dimensions 52x57x1309
Connections M12-12 poles + M12-5 poles (Active Unit)
Storage temperature -25…+ 70°C
Material Painted aluminum / PMMA / PBT Valox 508
Vibrations Width 0.35 mm, frequency 10 … 55Hz; 20 sweep per axis, 1octave/min (EN 60068-2-6)
Shocks 16 ms (10 G) 1,000 shocks per axis (EN 60068-2-29)

Test/Approvals

EMC compatibility According to 2014/30/EU Directive

Generical Data

Dimensions 52x56,9x1309,35 mm
Operating Temperature 0…+55°C
Humidity 15 … 95 % (no condensation)
Mechanical Protection IP65