SG4 Extended

957901400

SG4-30-105-OO-P

Type 4 safety light curtain with advanced functionality

  • No dead zone
  • Pigtail cable with M12 connector
  • Cascade connection of up to 3 units
  • Up to 20m operating range and 1800m protected height
  • Compact dimensions (35 x 41 mm section)
  • Anti-interference coding
  • Integrated Muting function
  • Floating Blanking, Fixed Blanking and Reduced Resolution
  • Configurable with:
  • Pushbuttons for common configuration
  • Graphic User Interface for complete parametrisation
  • Ethernet Interface for programming, monitoring and error logging



Technical features

Detection properties

Nominal sensing distance 0,2 … 20 m
Resolution 30mm
controlled height 1050 mm
number of rays 56
Sensitivity adjustment Teach-in/GUI
Effective Aperture Angle ≤ ±2,5°

Application

Function Principle Emitter + Receiver
Available functions Programmable Muting & Blanking
Description Compact no-dead-zone programmable
Functions Hand prot. res. 30 mm programmable

Safety parameters

Type Type 4 safety light curtain (A/M)
SIL 3
SILCL 3
PL e
PFHd 8,40E-09
Dcavg 98,80%
MTTFd 131 years

Outputs

Output type 2 x PNP-NO (OSSD safety output) with EDM
Response time 23 ms
Response Time (Master + Slave) Tcascade [ms] = Tmaster + Tslave1 + 7,5
Response Time (Master + 2 Slave) Tcascade [ms] = Tmaster + Tslave1 + Tslave2 + 7,5

Electrical data

Operating Voltage 24 Vdc ± 20%
Load current ≤ 500mA each output
Emission Infrared LED (950 nm wavelength)
Interference to external light According to IEC 61496-2
Power Consumption - Receiver ≤ 5W (no load)
Power Consumption - Emitter ≤ 3W
Cabel Length (Power Supply/Output) ≤ 50m
Cable Length for Master Slave Interconnections ≤ 1m (Master-Slave Cable)

Mechanical data

Dimensions 35x41x1056
Connections M12-5 poles pig-tail (emitter) M12-12 poles + M12-5poles / M12-12 poles pig-tails (receiver)
Storage temperature -25…+ 70°C
Material Painted aluminum / PMMA / PBT Valox 508 / PC LEXAN
Vibrations Width 0.35 mm, frequency 10 … 55Hz; 20 sweep per axis, 1octave/min (EN 60068-2-6)
Shocks 16 ms (10 G) 1,000 shocks per axis (EN 60068-2-29)

Test/Approvals

EMC compatibility According to 2014/30/EU Directive

Accessories

Supplied Accessories Standard "L" Mounting Brackets: 4 pcs kit

Generical Data

Network Interface Ethernet TCP/IP
Dimensions 35x40,75x1056,3 mm
Operating Temperature 0…+50°C
Humidity 15 … 95 % (no condensation)
Mechanical Protection IP65