Technical features

Detection properties

Nominal sensing distance 10mm
Operanting distance 0…8,1mm
Standard target 30x30mm FE360
Correction Factor copper: 0,40 / aluminium: 0,50 / brass: 0,55 / stainless steel: 0,75
Thermal drift of Sr < 10%
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis 1 … 20%

Application

Description M30 standard flush mount
Functions Proximity

Outputs

Output type TRIAC
Output Function NO
Switching frequency 25Hz

Electrical data

Operating Voltage 20...250Vac/50...60Hz
Load current 5...300mA
Leakage current ≤ 1mA RMS max
Output voltage drop See curves
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 200ms
Inrush current 7A (Ton = 10ms)

Mechanical data

Mounting Shielded
Dimensions M30 x 1,5 / L = 75,8mm
Weight 30g
Housing Material Nickel-plated brass
Connections M12 plug
Active Head Material PBT
Tightening torque 50Nm
Operating temperature -25°C…+70°C
Material Nickel-plated brass
Diameter/Dimension M30

Test/Approvals

Approvals CE UR
EMC compatibility IEC 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27
Degree of protection IP67

Accessories

Supplied Accessories 2 nuts M30x1.5

Generical Data

Dimensions M30 x 1,5 / L = 75,8mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67