VK

VK2/C0-1H

Ind.M18,2 wires AC-NC,M12 plug,Sch-STD

Cylindrical M18 in AC inductive sensors

  • Output: cable and M12 plug cable exit
  • Models with 2 wires
  • IP 67 protection degree
  • Multivoltage 20 ...253 Vac

       


Indicative image

Technical features

Detection properties

Nominal sensing distance 5mm
Operanting distance 0…4,05mm
Standard target 18x18mm FE360
Correction Factor copper: 0,35 / aluminium: 0,40 / brass: 0,50 / stainless steel: 0,80
Thermal drift of Sr < 10%
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis 1 … 20%

Application

Description M18 standard flush mount
Functions Proximity

Outputs

Output type TRIAC
Output Function NC
Switching frequency 25Hz

Electrical data

Operating Voltage 20...250Vac/50...60Hz
Load current 5...300mA
Leakage current ≤ 1mA RMS max
Output voltage drop See curves
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 200ms
Inrush current 7A (Ton = 10ms)

Mechanical data

Mounting Shielded
Dimensions M18 x 1 / L = 73,3mm
Weight 30g
Housing Material Nickel-plated brass
Connections M12 plug
Active Head Material PBT
Tightening torque 25Nm
Operating temperature -25°C…+70°C
Material Nickel-plated brass
Diameter/Dimension M18

Test/Approvals

Approvals CE UR
EMC compatibility IEC 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27
Degree of protection IP67

Accessories

Supplied Accessories 2 nuts M18x1

Generical Data

Dimensions M18 x 1 / L = 73,3mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67