Technical features

Detection properties

Nominal sensing distance 4mm
Operanting distance 0…3,2mm
Standard target 12x12mm FE360
Correction Factor copper: 0,48 / aluminium: 0,54 / brass: 0,60 / stainless steel: 0,86
Thermal drift of Sr < 10%
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis 1 … 20%

Application

Description M12 standard flush mount
Functions Proximity

Outputs

Output type MOSFET
Output Function NO (Vac) - NO/NC (Vdc)
Switching frequency 25Hz (AC) - 750Hz (DC)

Electrical data

Operating Voltage 20...250Vac/50...60Hz...20...250Vdc
Load current 5…140ma(Vac) - 5…200mA (Vdc)
Leakage current ≤ 1mA (Vac) - ≤ 0,7mA (Vdc)
Output voltage drop ≤ 7,5V (Vac) - ≤ 8V (Vdc)
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤100ms
Short-circuit protection Yes
Impulsive Overvoltage Protection Yes
Inrush current 600mA/150ms (AC/DC)
0,1µF @Vmax - 1µF @Vmin 1µF @Vmax - 1µF @Vmin

Mechanical data

Mounting Shielded
Dimensions M12 x 1 / L = 60mm
Weight 80g
Housing Material Nickel-plated brass
Connections 2m PUR Cable
Active Head Material PA4T
Tightening torque 6Nm
Operating temperature -25°C…+70°C
Material Nickel-plated brass
Diameter/Dimension M12

Test/Approvals

Approvals CE cULus
EMC compatibility IEC 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27
Degree of protection IP67

Accessories

Supplied Accessories 2 nuts M12x1

Generical Data

Dimensions M12 x 1 / L = 60mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67