PM3

PM3/00-2A

Ind.M12,NPN/PNP-NO/NC,Cable,Nsch-STD

M12 DECOUT® cylindrical inductive sensors

  • Wide range of models: standard, DECOUT® output
  • Output: cable, M12 plug cable exit
  • Models with 4 wires
  • ATEX models, cat. 3, available on request

   


Indicative image

Technical features

Detection properties

Nominal sensing distance 4mm
Operanting distance 0…3,2mm
Standard target 12x12mm FE360
Correction Factor copper: 0,52 / aluminium: 0,57 / brass: 0,62 / stainless steel: 0,87
Thermal drift of Sr < 10%
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis 1 … 20%

Application

Description M12 standard no-flush mount
Functions Proximity

Outputs

Output type NPN/PNP
Output Function NO/NC
Switching frequency 1kHz

Electrical data

Operating Voltage 10...30Vdc
No-Load supply current ≤ 30mA
Load current ≤ 100mA
Leakage current ≤ 10μA
Output voltage drop ≤ 1,2V @100mA
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤100ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Impulsive Overvoltage Protection Yes
Protection against inductive loads Yes

Mechanical data

Mounting Unshielded
Dimensions M12 x 1 / L = 65mm
Weight 66g
Housing Material Nickel-plated brass
Connections 2m PVC Cable
Active Head Material PBT
Tightening torque 10Nm
Operating temperature -25°C…+70°C
Material Nickel-plated brass
Diameter/Dimension M12

Test/Approvals

Approvals CE
EMC compatibility IEC 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27
Degree of protection IP67

Accessories

Supplied Accessories 2 nuts M12x1

Generical Data

Dimensions M12 x 1 / L = 65mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67