Technical features

Detection properties

Nominal sensing distance 4mm
Operanting distance 0…3,24mm
Standard target 12x12mm FE360
Correction Factor copper: 0,33 / aluminium: 0,40 / brass: 0,50 / stainless steel: 0,80
Thermal drift of Sr < 10%
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis 1 … 20%

Application

Description M12 standard no-flush mount
Functions Proximity

Outputs

Output type PNP
Output Function NO + NC
Switching frequency 2kHz

Electrical data

Operating Voltage 10...30Vdc
No-Load supply current ≤ 15mA
Load current ≤ 200mA
Leakage current ≤ 15μA
Output voltage drop ≤ 2V @200mA
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 50ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Impulsive Overvoltage Protection Yes
Protection against inductive loads Yes

Mechanical data

Mounting Unshielded
Weight 30g
Housing Material AISI316L Stainless Steel
Connections M12 Plug
Active Head Material PPS
Tightening torque 25Nm
Material AISI316L Stainless Steel
Diameter/Dimension M12

Test/Approvals

Approvals CE cULus ECOLAB DIVERSEY II 3G Ex nA IIC T5 Gc II 3D Ex tc IIIB T85°C Dc
EMC compatibility IEC 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27

Accessories

Supplied Accessories 2 nuts M12x1

Generical Data

Dimensions M12 x 1 / L = 64,6mm
Operating Temperature -40°C…+80°C (up to 100°C for short exposure during cleaning process)
Mechanical Protection IP67