Technical features

Detection properties

Nominal sensing distance 8mm
Operanting distance 0…6,48mm
Standard target 24x24mm FE360
Correction Factor copper: 0,20 / aluminium: 0,30 / brass: 0,40 / stainless steel: 0,65
Thermal drift of Sr < 10%
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis 1 … 20%

Application

Description M18 standard flush mount
Functions Proximity

Outputs

Output type NPN
Output Function NO + NC
Switching frequency 1,5kHz

Electrical data

Operating Voltage 10...30Vdc
No-Load supply current ≤ 15mA
Load current ≤ 200mA
Leakage current ≤ 10μA
Output voltage drop ≤ 2V @200mA
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 50ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Impulsive Overvoltage Protection Yes
Protection against inductive loads Yes

Mechanical data

Mounting Shielded
Weight 55g
Housing Material AISI316L Stainless Steel
Connections M12 Plug
Active Head Material PPS
Tightening torque 50Nm
Material AISI316L Stainless Steel
Diameter/Dimension M18

Test/Approvals

Approvals CE cULus ECOLAB DIVERSY
EMC compatibility IEC 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27

Accessories

Supplied Accessories 2 nuts M18x1

Generical Data

Dimensions M18 x 1 / L = 63,1mm
Operating Temperature -40°C…+80°C (up to 100°C for short exposure during cleaning process)
Mechanical Protection IP67