Technical features

Detection properties

Nominal sensing distance 1,5mm
Operanting distance 0…1,21mm
Standard target 8x8mm FE360
Correction Factor copper: 0,29 / aluminium: 0,38 / brass: 0,49 / stainless steel: 0,78
Thermal drift of Sr < 10%
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis 1 … 20%

Application

Description M8 standard flush mount
Functions Proximity

Outputs

Output type PNP
Output Function NO
Switching frequency 5kHz

Electrical data

Operating Voltage 10...30Vdc
No-Load supply current ≤ 10mA
Load current ≤ 200mA
Leakage current ≤ 10μA
Output voltage drop ≤ 1,8V @200mA
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 50ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Impulsive Overvoltage Protection Yes
Protection against inductive loads Yes

Mechanical data

Mounting Shielded
Housing Material Nickel-plated brass
Connections 5m PVC Cable
Active Head Material PBT
Tightening torque 3Nm
Material Nickel-plated brass
Diameter/Dimension M8

Test/Approvals

Approvals CE UR
EMC compatibility IEC 60947-5-2
Shocks and vibrations Vibration IEC 60068-2-6 / Shock IEC 60068-2-27

Accessories

Supplied Accessories 2 nuts M8x1

Generical Data

Dimensions M8 x 1 / L = 45,5mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67