Detection properties

Nominal sensing distance 1mm
Operanting distance 0…0,81mm
Standard target 8x8mm FE360
Correction Factor copper: 0,2…0,5 / aluminium: 0,3...0,5 / brass: 0,4...0,6 / stainelss steel: 0,7…0,9
Repeat Accuracy < 3% (UB 24V Ta=23°C ±5°C)
Hysteresis < 10%

Application

Description M8 NAMUR flush mount
Functions Proximity

Outputs

Output type NAMUR
Output Function NAMUR
Switching frequency 2kHz
Response time 0,25

Electrical data

Operating Voltage 7,7...9Vdc
No-Load supply current < 1mA (target absent)
Load current < 3mA (target present)
Max ripple content ≤ 10%
Short-circuit protection Yes
Reverse Polarity Protection Yes
Emission ≥100kHz
Protection against inductive loads Yes

Mechanical data

Mounting Shielded
Dimensions Ø8x53
Housing Material Nickel-plated brass
Connections M12 Plug
Active Head Material LCP
Tightening torque 2Nm
Material Nickel-plated brass
Diameter/Dimension M8

Test/Approvals

Approvals CE cULus

Accessories

Supplied Accessories 2 nuts M8x1

Generical Data

Dimensions Ø8 / L = 53mm
Operating Temperature -25°C…+60°C
Mechanical Protection IP67