Technical features

Detection properties

Nominal sensing distance 0,8mm
Operanting distance 0…0,65mm
Standard target 5x5mm FE360
Correction Factor copper: 0,2…0,5 / aluminium: 0,3...0,5 / brass: 0,4...0,6 / stainelss steel: 0,7…0,9
Repeat Accuracy < 3% (UB 24V Ta=23°C ±5°C)
Hysteresis < 10%

Application

Description M5 NAMUR flush mount
Functions Proximity

Outputs

Output type NAMUR
Output Function NAMUR
Switching frequency 2kHz
Response time 0,25

Electrical data

Operating Voltage 6...12Vdc
No-Load supply current < 1mA (target absent)
Load current < 3mA (target present)
Max ripple content ≤ 10%
Short-circuit protection Yes
Reverse Polarity Protection Yes
Emission ≥100kHz
Protection against inductive loads Yes

Mechanical data

Mounting Shielded
Dimensions Ø5x20
Housing Material Stainless steel
Connections 2m PVC Cable
Active Head Material LCP
Tightening torque 1,5Nm
Material Stainless steel
Diameter/Dimension M5

Test/Approvals

Approvals CE cULus

Accessories

Supplied Accessories 2 nuts M5x0.5

Generical Data

Dimensions Ø5 / L = 20mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67