Technical features

Detection properties

Nominal sensing distance 1,5mm
Operanting distance 0…1,21mm
Standard target 8x8mm FE360
Correction Factor copper: 0,2…0,5 / aluminium: 0,3…0,5 / brass: 0,4…0,6 / stainelss steel: 0,7…0,9
Repeat Accuracy < 3% (UB 24V Ta=23°C ±5°C)
Hysteresis < 10%

Application

Description M8 standard flush mount
Functions Proximity

Outputs

Output type NPN
Output Function NC
Switching frequency 1kHz
Response time 0,5

Electrical data

Operating Voltage 10...30Vdc
No-Load supply current ≤ 10mA
Load current 200mA
Output voltage drop ≤ 1,2V @100mA
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 50ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Emission ≥100kHz
Protection against inductive loads Yes

Mechanical data

Mounting Shielded
Dimensions Ø8x51
Housing Material Nickel-plated brass
Connections 2m PVC Cable
Active Head Material LCP
Tightening torque 2Nm
Material Nickel-plated brass
Diameter/Dimension M8

Test/Approvals

Approvals CE cULus

Accessories

Supplied Accessories 2 nuts M8x1

Generical Data

Dimensions Ø8 / L = 51mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67