Detection properties

Nominal sensing distance 0,8mm
Operanting distance 0…0,65mm
Standard target 4x4mm FE360
Correction Factor copper: 0,2…0,5 / aluminium: 0,3…0,5 / brass: 0,4…0,6 / stainelss steel: 0,7…0,9
Repeat Accuracy < 3% (UB 24V Ta=23°C ±5°C)
Hysteresis < 10%

Application

Description M4 standard flush mount
Functions Proximity

Outputs

Output type PNP
Output Function NO
Switching frequency 2kHz
Response time 0,25

Electrical data

Operating Voltage 10...30Vdc
No-Load supply current ≤ 10mA
Load current 100mA
Output voltage drop < 1,5V
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Short-circuit protection Yes
Reverse Polarity Protection Yes
Emission ≥100kHz
Protection against inductive loads Yes

Mechanical data

Mounting Shielded
Dimensions Ø4x25
Housing Material Stainless steel
Connections 2m PVC Cable
Active Head Material POM
Material Stainless steel
Diameter/Dimension M4

Test/Approvals

Approvals CE

Generical Data

Dimensions Ø4 / L = 25mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP69K