Inductive AC

95B060780

IS-18-A15-S2

Cylindrical inductive sensors with analogue output

  • Wide choice of sizes M8, M12 and M18
  • Wide usable sensing ranges: 4 mm for M8, 6 mm for M12 and 10 mm for M18
  • Excellent resolution (no digitalization)
  • Excellent temperature stability at low distances
  • Voltage and current output in the same device (M12 and M18 only)



Technical features

Detection properties

Nominal sensing distance 5mm
Operanting distance 0…4,05mm
Standard target 18x18mm FE360
Correction Factor copper: 0,24…0,45 / aluminium: 0,3...0,45 / brass: 0,3...0,5 / stainelss steel: 0,6…1
Repeat Accuracy < 5% (UB 24V Ta=23°C ±5°C)
Hysteresis < 10%

Application

Description M18 flush mount VAC type
Functions Proximity

Outputs

Output type SCR
Output Function NO
Switching frequency 25Hz
Response time 20

Electrical data

Operating Voltage 20...250Vac/50...60Hz
No-Load supply current ≤ 0,7mA
Load current 500mA; inrush: 1,5A
Output voltage drop ≤ 4V @100mA
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability < 300ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Emission ≥100kHz
Protection against inductive loads Yes

Mechanical data

Mounting Shielded
Dimensions Ø18x65
Housing Material Nickel-plated brass
Connections M12 Plug
Active Head Material PA16
Tightening torque 20Nm
Material Nickel-plated brass
Diameter/Dimension M18

Test/Approvals

Approvals CE cULus

Accessories

Supplied Accessories 2 nuts M18x1

Generical Data

Dimensions Ø18 / L = 65mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67