Nominal sensing distance | According to the sensors used: LS2 up to 12m LS4 up to 20m |
Function Principle | Control unit | |
Available functions | Manual/Automatic Restart, EDM, System Status, Muting, Override | |
Description | Cat. 4 Safety Module with integrated Muting function | |
Usable with | Safety light curtains: LS2, LS4, LP4 | |
Max. number of sensors connected | 1 x LS2/LS4 receiver | |
Max. number of muting sensors | 2 x PNP-NO | |
Muting lamp output | 24V - 0,5 … 5W | |
Functions | Relays modules |
Type | 4 | |
SIL | 4 | |
SILCL | 4 | |
PL | d (2A@230VAC; 1 comm. @30s) e (2A@230VAC; 1 comm. @60s) e (2A@230VAC; 1 comm. @1h) e (2A@230VAC; 1 comm. @24h) d (0,5A@230VAC; 1 comm. @30s) d (0,5A@230VAC; 1 comm. @60s) e (0,5A@230VAC; 1 comm. @1h) e (0,5A@230VAC; 1 comm. @24h) | |
PFHd | 2,08E-08 (2A@230VAC; 1 comm. @30s) 1,71E-08 (2A@230VAC; 1 comm. @60s) 6,588E-09 (2A@230VAC; 1 comm. @1h) 6,42E-09 (2A@230VAC; 1 comm. @24h) 5,03E-08 (0,5A@230VAC; 1 comm. @30s) 2.80E-08 (0,5A@230VAC; 1 comm. @60s) 6,76E-09 (0,5A@230VAC; 1 comm. @1h) | |
Dcavg | 98,89% (2A@230VAC; 1 comm. @30s) 98,78% (2A@230VAC; 1 comm. @60s) 98,78% (2A@230VAC; 1 comm. @1h) 96,25% (2A@230VAC; 1 comm. @24h) 98,94% (0,5A@230VAC; 1 comm. @30s) 98,89% (0,5A@230VAC; 1 comm. @60s) 97,01% (0,5A@230VAC; 1 comm. @1h) 96,28% (0,5A@23 | |
MTTFd | 25,97 (2A@230VAC; 1 comm. @30s) 49,42 (2A@230VAC; 1 comm. @60s) 100 (2A@230VAC; 1 comm. @1h) 100 (2A@230VAC; 1 comm. @24h) 13,25 (0,5A@230VAC; 1 comm. @30s) 25,97 (0,5A@230VAC; 1 comm. @60s) 100 (0,5A@230VAC; 1 comm. @1h) 100 (0,5A@230VAC; 1 comm. @2 | |
CFF | 80% |
Output type | 2 x relay NO (OSSD safety output) 1 x NO, 100mA, 24V (System Status) | |
Response time | ≤ 20ms | |
Override Time-out | 15 min |
Operating Voltage | 24Vdc ± 20% | |
Load current | 2A @ 250V | |
Cabel Length (Power Supply/Output) | ≤ 100m | |
Cable Length (sensors) | ≤ 100m | |
Power Consumption | ≤ 5W |
Dimensions | 35 x 99 x 114,5 mm | |
Connections | terminals | |
Operating temperature | 0°C … + 55°C |
Approvals | CE, cULus, TÜV | |
EMC compatibility | According to 2014/30/EU Directive | |
Degree of protection | IP20 |
Dimensions | 35 x 99 x 114,5 mm | |
Operating Temperature | 0°C … + 55°C | |
Mechanical Protection | IP20 |